Floor Assembly Acoustic Calculations
Last updated February 10, 2025
By Ian Story
Reference
2019 AWC Technical Report No. 15
Baseline Floor Assembly
19/32″ plywood over 2×10 floor joists w/ 3 1/2″ fiberglass batt insulation. Use RC channels @ 24″ o/c w/ 5/8″ gypsum board. Flooring is worst-case for each frequency.

Increasing Insulation
19/32″ plywood over 2×10 floor joists w/ 8 1/4″ mineral wool insulation. Use RC channels @ 24″ o/c w/ 5/8″ gypsum board. Flooring is worst-case for each frequency.

(2) Layers GWB
19/32″ plywood over 2×10 floor joists w/ 8 1/4″ mineral wool insulation. Use RC channels @ 24″ o/c w/ (2) layers 5/8″ gypsum board. Flooring is worst-case for each frequency.

Thicker OSB Sheathing
23/32″ OSB over 2×10 floor joists w/ 8 1/4″ mineral wool insulation. Use RC channels @ 24″ o/c w/ (2) layers 5/8″ gypsum board. Flooring is worst-case for each frequency.